Power System Dynamics & Stability
(Note: please fill in your genuine name and institutional email in the following request forms. Fake name or personal email address will NOT be responded.)
IEEE Tranmission Power System Tesbeds
IEEE 118-bus, 19 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-69; disturbance: fault happens at bus-47 from 1sec to 1.2sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from a MATPOWER format static data file, and from a DIgSILENT format dynamic data file at 118_bus_dig)
Request form
IEEE 162-bus, 17 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-108; disturbance: fault happens at bus-4 from 0.1sec to 0.2sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from a IEEE format static data file, and from a BPA format dynamic (generator) data file)
Request form
IEEE 145-bus, 50 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-145; disturbance: fault happens at bus-34 from 1sec to 1.1sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from a IEEE format power flow file, and from a BPA format (dynamic) generator file)
Request form
IEEE 140-bus, 48 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-27; disturbance: fault happens at bus-111 from 0.1sec to 0.6sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from PST format files)
Request form
IEEE 39-bus, 10 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-31; disturbance: fault happens at bus-5 from 1sec to 1.2sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from PST format files)
Request form
IEEE 300-bus, 69 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-10055; disturbance: fault happens at bus-1 from 1sec to 1.1sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from the PowerWorld format files. The original PowerWorld files are prepared by a team from University of Cyprus link.
Also, appreciate Prof. Adam Birchfield of the TAMU synthetic power grid team for the help in PowerWorld link)
Request form
UTK 944-bus, 144 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-76; disturbance: fault happens at bus-1 from 2sec to 2.1sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from PSS/E format files)
Request form
TAMU Texas 2000-bus, 533 generators (PSAT/MATLAB format)
(unit: rad; ref. machine: the generator at bus-7098; disturbance: fault happens at bus-1001 from 3sec to 3.1sec)
Rotor Angle Response | Single line diagram |
---|---|
![]() | ![]() |
(Note: the PSAT/MATLAB file is converted manually from PSS/E format files. The original PSS/E files are prepared by the TAMU synthetic power grid team led by Prof. Adam Birchfield and Prof. Thomas Overbye link)
Request form
IEEE Distribution Power System Tesbeds
(Coming soon...)
Disclaimer
- These MATLAB files are manually created based on the above-mentioned third-party source files shared by the academic community. The data in those source files can differ from other publishers’.
- Due to the inherent complicatedness of power system dynamic simulation and the different numerical solver characteristics of open-source/commercial simulators, we do not guarantee the reproducibility of other researchers’ papers using the data file provided here.
- If these data files are used in your publications, please feel free to cite the web address here, which can give me some encouragement to continue converting more data.